Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual
Page 67
Rockwell Automation Publication GMC-RM003C-EN-P - September 2013
67
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Performance Specifications with Frame 70 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
LDAT-S053010-DBx
4.1
9.4
378 (85)
34.2
1093 (246)
1.31
2094-AM02-S
LDAT-S053020-DBx
5.0
1.53
LDAT-S053030-DBx
…
LDAT-S053050-DBx
5.0
1.53
LDAT-S053010-EBx
…
LDAT-S053050-EBx
1.7
3.1
11.4
0.47
2094-AMP5-S
LDAT-S054010-DBx
4.4
12.4
509 (114)
45.5
1453 (327)
1.87
2094-AM02-S
LDAT-S054020-DBx
…
LDAT-S054050-DBx
5.0
2.05
LDAT-S054010-EBx
…
LDAT-S054050-EBx
2.6
6.2
22.7
1.02
2094-AM01-S
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 6000
200V-class Drives
LDAT-S072010-DBx
…
LDAT-S072070-DBx
3.5
6.0
364 (82)
22.0
1055 (237)
1.03
2094-AM01-S
LDAT-S072010-EBx
…
LDAT-S072070-EBx
1.7
3.0
11.0
0.47
2094-AMP5-S
LDAT-S073010-DBx
…
LDAT-S073070-DBx
3.5
9.0
554 (125)
32.8
1576 (354)
1.57
2094-AM02-S
LDAT-S073010-EBx
…
LDAT-S073070-EBx
1.2
3.0
10.9
0.41
2094-AMP5-S
LDAT-S074010-DBx
…
LDAT-S074070-DBx
3.5
11.9
730 (164)
43.5
2088 (469)
2.08
2094-AM02-S
LDAT-S074010-EBx
…
LDAT-S074070-EBx
1.8
6.0
21.7
0.95
2094-AM01-S
LDAT-S076010-DBx
…
LDAT-S076070-DBx
3.5
18.2
1122 (252)
66.4
3189 (717)
3.17
2094-AM03-S
LDAT-S076010-EBx
…
LDAT-S076070-EBx
1.8
9.1
33.2
1.45
2094-AM02-S
Performance Specifications with Frame 50 Linear Thruster (continued)
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 6000
200V-class Drives