Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual
Page 76

76
Rockwell Automation Publication GMC-RM003C-EN-P - September 2013
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Performance Specifications with Frame 50 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 6000
400V-class Drives
Kinetix 6200/6500
400V-class Drives
LDAT-S051010-DBx
2.8
3.1
119 (27)
11.4
363 (82)
0.34
2094-BMP5-S
@ 150%
2094-BMP5-M
LDAT-S051020-DBx
3.7
0.43
LDAT-S051030-DBx
4.1
0.49
LDAT-S051040-DBx
4.4
0.53
LDAT-S051050-DBx
4.7
0.55
LDAT-S052010-DBx
3.7
6.2
251 (56)
22.7
727 (163)
0.92
2094-BM01-S
@ 150%
2094-BM01-M
LDAT-S052020-DBx
4.8
1.20
LDAT-S052030-DBx
5.0
1.24
LDAT-S052040-DBx
LDAT-S052050-DBx
LDAT-S052010-EBx
3.7
3.1
11.4
0.80
2094-BMP5-S
@ 150%
2094-BMP5-M
LDAT-S052020-EBx
4.6
0.98
LDAT-S052030-EBx
4.6
1.02
LDAT-S052040-EBx
LDAT-S052050-EBx
LDAT-S053010-DBx
4.1
9.4
378 (85)
34.2
1093 (246)
1.56
2094-BM02-S
@ 150%
2094-BM02-M
LDAT-S053020-DBx
5.0
1.87
LDAT-S053030-DBx
…
LDAT-S053050-DBx
LDAT-S053010-EBx
…
LDAT-S053050-EBx
3.5
3.1
11.4
1.04
2094-BMP5-S
@ 150%
2094-BMP5-M
LDAT-S054010-DBx
4.4
12.4
509 (114)
45.5
1453 (327)
2.26
2094-BM02-S
@ 150%
2094-BM02-M
LDAT-S054020-DBx
…
LDAT-S054050-DBx
5.00
2.53
LDAT-S054010-EBx
4.4
6.2
22.7
1.87
2094-BM01-S
@ 150%
2094-BM01-M
LDAT-S054020-EBx
…
LDAT-S054050-EBx
5.0
2.05