LDL-Series Performance Specifications with Kinetix 6000 (200V-class) Drives (continued)
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Kinetix 6000 (200V-class) Drives/LDL-Series Linear Motor Curves
Linear Motor
Speed, max
m/s (ft/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Linear Motor Rated
Output
kW
Kinetix 6000
200V-class Drives
LDL-N050120-DHT
10.0 (32.8)
2.7
96 (22)
9.1
317 (71)
0.48
2094-AMP5-S
LDL-N050240-DHT
5.5
191 (43)
18.1
635 (143)
0.95
2094-AM01-S
LDL-N050240-EHT
2.7
9.1
2094-AMP5-S
LDL-N050360-DHT
8.2
287 (65)
27.2
952 (214)
1.43
2094-AM02-S
LDL-N050360-EHT
2.7
9.1
2094-AMP5-S
LDL-N050480-DHT
10.9
383 (86)
36.3
1269 (285)
1.91
2094-AM03-S
LDL-N050480-EHT
5.5
18.1
2094-AM01-S
LDL-T050120-DHT
2.7
110 (25)
9.1
364 (82)
0.55
2094-AMP5-S
LDL-T050240-DHT
5.5
220 (49)
18.1
728 (164)
1.10
2094-AM01-S
LDL-T050240-EHT
2.7
9.1
2094-AMP5-S
LDL-T050360-DHT
8.2
329 (74)
27.2
1093 (246)
1.64
2094-AM02-S
LDL-T050480-DHT
10.9
439 (99)
36.3
1457 (327)
2.19
2094-AM03-S
LDL-T050480-EHT
5.5
18.1
2094-AM01-S
LDL-N075480-DHT
10.0 (32.8)
9.9
519 (117)
32.8
1723 (387)
2.59
2094-AM03-S
LDL-N075480-EHT
4.9
16.4
2094-AM01-S
LDL-T075480-DHT
9.9
596 (134)
32.8
1977 (444)
2.98
2094-AM03-S
LDL-T075480-EHT
4.9
16.4
2094-AM01-S
250
200
150
100
50
0
56.2
45.0
33.7
22.5
11.2
0
2094-AMP5-S and LDL-N030120-DHT
Force
(N)
Force
(lb)
Velocity (m/s)
2
8
6
0
12
10
4
500
400
300
200
100
0
112
89.9
67.4
45.0
22.4
0
2094-AM01-S and LDL-N030240-DHT
2094-AMP5-S and LDL-N030240-EHT
Force
(N)
Force
(lb)
Velocity (m/s)
2
8
6
0
12
10
4
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region