Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual
Page 34

34
Rockwell Automation Publication GMC-RM003C-EN-P - September 2013
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Kinetix 6000 (200V-class) Drives/MP-Series Medium Inertia Motor Curves
Bulletin MPM Motor Performance Specifications with Kinetix 6000 (200V-class) Drives
Rotary Motor
Speed,
base
rpm
Speed,
max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW
Kinetix 6000
200V-class Drives
MPM-A1151M
4500
6000
7.65
2.3 (20.3)
30.0
6.5 (57.5)
0.90
2094-AM02-S
30.5
6.6 (58.4)
2094-AM03-S
MPM-A1152F
3000
5000
11.93
4.7 (41.6)
30.0
9.9 (87.6)
1.40
2094-AM02-S
44.8
13.5 (119)
2094-AM03-S
MPM-A1153F
3000
5000
16.18
6.0 (53.1)
30.0
10.7 (94.7)
1.45
2094-AM02-S
6.5 (57.5)
49.0
16.1 (142)
2094-AM03-S
MPM-A1302F
3000
4500
17.28
6.6 (58.4)
49.0
13.2 (117)
1.65
2094-AM03-S
50.2
13.5 (119)
2094-AM05-S
MPM-A1304F
3000
4000
19.65
7.6 (67.2)
30.0
13.2 (117)
2.20
2094-AM02-S
9.2 (81.4)
48.3
19.3 (171)
2094-AM03-S
MPM-A1651F
3000
5000
30.96
9.3 (82.3)
49.0
15.2 (134)
2.50
2094-AM03-S
10.7 (94.7)
73.4
20.3 (179)
2094-AM05-S
MPM-A1652F
3000
4000
33.54
11.0 (97.3)
49.0
19.7 (174)
4.03
2094-AM03-S
13.4 (119)
73.4
27.7 (245)
2094-AM05-S
MPM-A1653F
3000
4000
42.4
11.7 (103)
49.0
21.1 (187)
5.10
2094-AM03-S
18.6 (165)
73.4
29.6 (262)
2094-AM05-S
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-AM03-S and MPM-A1151M
1000
4000
3000
0
6000
5000
2000
8.85
17.7
26.5
35.4
44.2
53.1
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
61.9
0
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-AM03-S and MPM-A1152F
17.7
35.4
53.1
70.8
88.5
106
0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
124
0
0
3000
5000
4000
1000
2000
= Intermittent operating region
= Continuous operating region