Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual
Page 41

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013
41
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Kinetix 6000/Kinetix 6200/6500 (400V-class) Drives/MP-Series Medium Inertia Motor Curves (continued)
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM02-S @ 250% or 2094-BM02-M
and MPM-B1153F
26.5
53.1
79.6
106
133
159
0
3.0
6.0
9.0
12.0
15.0
18.0
21.0
186
0
1000
4000
3000
0
6000
5000
2000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM03-S @ 150% or 2094-BM03-M
and MPM-B1153T
26.5
53.1
79.6
106
133
159
0
3.0
6.0
9.0
12.0
15.0
18.0
21.0
186
0
0
6000
8000
2000
4000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM02-S @ 250% or 2094-BM02-M
and MPM-B1302M
1000
4000
3000
0
6000
5000
2000
17.7
35.4
53.1
70.8
88.5
106
0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
124
0
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM01-S @ 250% or 2094-BM01-M
and MPM-B1302F
17.7
35.4
53.1
70.8
88.5
106
0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
124
0
0
3000
5000
4000
1000
2000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM03-S @ 150% or 2094-BM03-M
and MPM-B1302T
17.7
35.4
53.1
70.8
88.5
106
0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
124
0
0
6000
8000
2000
4000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2094-BM01-S @ 250% or 2094-BM01-M
and MPM-B1304C
35.4
70.8
106
142
177
212
0
4.0
8.0
12.0
16.0
20.0
24.0
28.0
248
0
500
2000
1500
0
3000
2500
1000
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC rms input voltage