Stop
INPUT
BOOL[1…5]
TRUE to stop each element of the array.
Corresponds to each drive, for example, Stop
[1] for Drive 1 and Stop [5] for Drive5.
ReferenceSpeed
INPUT
REA[1...5]L
Reference speed to set the device speed.
Each element of the array corresponds to each
drive, for example, Reference Speed [1]
for Drive 1 and Reference Speed [5] for Drive5.
Jog
INPUT
BOOL[1...5]
TRUE to enable jog in PowerFlex drive.
Each element of the array corresponds to each
drive, for example, Reference Jog [1] for Drive
1 and Jog [5] for Drive5.
ClearFault
INPUT
BOOL[1...5]
TRUE to clear fault in PowerFlex drive.
Each element of the array corresponds to each
drive, for example, ClearFault [1] for Drive 1
and ClearFault [5] for Drive5.
Fwd_Rev
INPUT
BOOL[1...5]
TRUE to configure PowerFlex drive for forward
motion.
FALSE to configure PowerFlex drive for Reverse
motion.
Each element of the array corresponds to each
drive, for example, Fwd_Rev [1] for Drive 1 and
Fwd_Rev [5] for Drive5.
FBENO
OUTPUT
BOOL
Function block enable output.
TRUE upon exit.
PF_Feedback
OUTPUT
REAL[1...5]
Speed reference from the PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Feedback[1] for Drive 1
and PF_Feedback[5] for Drive5.
PF_Ready
OUTPUT
BOOL[1...5]
Ready bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Ready[1] for Drive 1 and
PF_Ready[5] for Drive5.
PF_Active
OUTPUT
BOOL[1...5]
Active bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Active[1] for Drive 1 and
PF_Active[5] for Drive5.
PF_Alarm
OUTPUT
BOOL[1...5]
Alarm bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Alarm[1] for Drive 1 and
PF_Alarm[5] for Drive5.
PF_Fault
OUTPUT
BOOL[1...5]
Fault bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Fault[1] for Drive 1 and
PF_Fault[5] for Drive5.
PF_AltReference
OUTPUT
BOOL[1...5]
Alt Reference bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_AltReference[1] for
Drive 1 and PF_AltReference[5] for Drive5.
IMPORTANT
Ensure that your PowerFlex drives settings are correct. For basic setup
configuration, see the PowerFlex drives user manuals in the
RA_PF_DNET_MULTIDRIVE: Input and Output Parameters
Variable Name
Type
Data Type
Description