PLC-5 Ethernet Interface Module (1785-ENET)

The following tables show measured performance data for the
1785-ENET module.

PLC-to-PLC (1 active MSG instruction)

Workstation-to-PLC (Solicited Asynchronous)

Operation:

Words:

MSG per second:

ms per MSG:

Words per second:

read

1

20.2

49.5

20

read

20

19.8

50.5

396

read

100

18.8

53.2

1,880

read

1000

10.6

94.3

10,600

write

1

21.4

46.7

21

write

20

21.3

46.9

426

write

100

20.4

49.0

2,040

write

1000

11.4

87.7

11,400

Operation:

Words:

MSG per second:

ms per MSG:

Words per second:

read

1

99.3

10.1

99

read

20

96.8

10.3

1,936

read

100

90.7

11.0

9,070

read

1000

54.7

18.2

54,700

write

1

102.6

9.7

102

write

20

100.4

10.0

2,008

write

100

94.0

10.6

9,400

write

1000

49.8

20.1

49,800