Rockwell Automation 1791ES-IB16 Guard I/O EtherNet/IP Safety Modules User Manual
Page 84
84
Rockwell Automation Publication 1791ES-UM001D-EN-P - May 2013
Appendix A
Get Diagnostic Status from Modules by Using Explicit Messaging
225 (549)
1791ES-
IB16
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety Input
4
Safety
Input 3
Safety Input
2
Safety
Input 1
Safety Input
0
1
Safety Input
15
Safety Input
14
Safety
Input 13
Safety Input
12
Safety
Input 11
Safety Input
10
Safety
Input 9
Safety Input
8
2
Safety Input
7
Status
Safety Input
6
Status
Safety
Input 5
Status
Safety Input
4
Status
Safety
Input 3
Status
Safety Input
2
Status
Safety
Input 1
Status
Safety Input
0
Status
3
Safety Input
15
Status
Safety Input
14
Status
Safety
Input 13
Status
Safety Input
12
Status
Safety
Input 11
Status
Safety Input
10
Status
Safety
Input 9
Status
Safety Input
8
Status
300 (768)
1791ES-
IB16
Standard Only
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Input Power
Error
301 (769)
1791ES-
IB8XOBV4
Standard Only
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Output
Power
Error
Input Power
Error
315 (789)
1791ES-
IB16
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety Input
4
Safety
Input 3
Safety Input
2
Safety
Input 1
Safety Input
0
1
Safety Input
15
Status
Safety Input
14
Status
Safety
Input 13
Status
Safety Input
12
Status
Safety
Input 11
Status
Safety Input
10
Status
Safety
Input 9
Status
Safety Input
8
Status
2
Combined
Safety In
Status
Reserved
Input
Power
Error
(1)
Reserved
Muting
Lamp 15
Status
Muting
Lamp 11
Status
Muting
Lamp 7
Status
Muting
Lamp 3
Status
324 (804)
1791ES-
IB8XOBV4
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety Input
4
Safety
Input 3
Safety Input
2
Safety
Input 1
Safety Input
0
1
Combined
Safety In
Status
Combined
Safety Out
Status
Input
Power
Error
(1)
Output
Power
Error
(1)
Reserved
Reserved
Muting
Lamp 7
Status
Muting
Lamp 3
Status
334 (820)
1791ES-
IB8XOBV4
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety Input
4
Safety
Input 3
Safety Input
2
Safety
Input 1
Safety Input
0
1
Safety Input
7
Status
Safety Input
6
Status
Safety
Input 5
Status
Safety Input
4 Status
Safety
Input 3
Status
Safety Input
2 Status
Safety
Input 1
Status
Safety Input
0 Status
2
Reserved
Reserved
Input
Power
Error
(1)
Output
Power
Error
Reserved
Reserved
Muting
Lamp 7
Status
Muting
Lamp 3
Status
335 (821)
1791ES-
IB16
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety Input
4
Safety
Input 3
Safety Input
2
Safety
Input 1
Safety Input
0
1
Safety Input
15
Safety Input
14
Safety
Input 13
Safety Input
12
Safety
Input 11
Safety Input
10
Safety
Input 9
Safety Input
8
2
Safety Input
7
Status
Safety Input
6
Status
Safety
Input 5
Status
Safety Input
4
Status
Safety
Input 3
Status
Safety Input
2
Status
Safety
Input 1
Status
Safety Input
0
Status
3
Safety Input
15
Status
Safety Input
14
Status
Safety
Input 13
Status
Safety Input
12
Status
Safety
Input 11
Status
Safety Input
10
Status
Safety
Input 9
Status
Safety Input
8
Status
4
Reserved
Reserved
Input
Power
Error
Reserved
Muting
Lamp 15
Status
Muting
Lamp 11
Status
Muting
Lamp 7
Status
Muting
Lamp 3
Status
Table 21 - Input Data (continued)
Instance
Hex
(Decimal)
Module
Connection
Type
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0