Rockwell Automation 1791ES-IB16 Guard I/O EtherNet/IP Safety Modules User Manual
Page 79

Rockwell Automation Publication 1791ES-UM001D-EN-P - May 2013
79
Get Diagnostic Status from Modules by Using Explicit Messaging
Appendix A
The layout of Instance 869 (365 Hex) is as follows.
From the top of the Message Configuration dialog box, choose the
Communication tab. This dialog box requires the path to the module.
Click Browse to browse to the module that the MSG will read.
365
1791ES-
IB16
Safety and
Standard
0
Safety Input
7
Safety Input
6
Safety
Input 5
Safety
Input 4
Safety
Input 3
Safety
Input 2
Safety
Input 1
Safety
Input 0
1
Safety Input
15
Safety Input
14
Safety
Input 13
Safety
Input 12
Safety
Input 11
Safety
Input 10
Safety
Input 9
Safety
Input 8
2
Safety Input
7
Status
Safety Input
6
Status
Safety
Input 5
Status
Safety
Input 4
Status
Safety
Input 3
Status
Safety
Input 2
Status
Safety
Input 1
Status
Safety
Input 0
Status
3
Safety Input
15
Status
Safety Input
14
Status
Safety
Input 13
Status
Safety
Input 12
Status
Safety
Input 11
Status
Safety
Input 10
Status
Safety
Input 9
Status
Safety
Input 8
Status
4
Safety
Output 7
Status
Safety
Output 6
Status
Safety
Output 5
Status
Safety
Output 4
Status
Safety
Output 3
Status
Safety
Output 2
Status
Safety
Output 1
Status
Safety
Output 0
Status
5
Safety
Output 15
Status
Safety
Output 14
Status
Safety
Output 13
Status
Safety
Output 12
Status
Safety
Output 11
Status
Safety
Output 10
Status
Safety
Output 9
Status
Safety
Output 8
Status
6
Reserved
Reserved
Input
Power
Error
(1)
Output
Power
Error
(1)
Muting
Lamp 15
Status
Muting
Lamp 11
Status
Muting
Lamp 7
Status
Muting
Lamp 3
Status