Dual trunk e1 router – Black Box LRU4240 User Manual
Page 140

128
SALES: 0118 965 5100
Dual Trunk E1 Router User’s Guide
Dual Trunk E1 Router
Table D-34 Menu-6B Multilink Frame Relay Port Configuration and Status
Table D-35 Menu-7 Feature Keys
Table D-36 Alarm Configuration
Protocol Error - Number of PPP/MLPPP protocol errors detected in this port.
Paramete
r
Description
Default
Port 1/2
Include In Bundle - Yes, No
Yes
Status - Normal, Idle, Down, Remote Not Configured, Inconsistent Bundle,
Unknown Vendor, Loopback Detected, Test Active, Remote Link Up, and Awaiting
Remote Link
(status)
Protocol Errors - number of MFR protocol errors detected on the port
(counter)
Local
Local Bundle Identifier - (status) local identifier for logical T1 bundle
(ID no.)
Remote Bundle Identifier - (status) remote identifier for logical T1 bundle
(ID no.)
Parameter
Default
RMON – PPP and Frame Relay RMON1 statistics
Capable
Service Level Agreement (Frame Relay SLA FRF.13)
Capable
RMON 2 - Protocols and application monitoring
Capable
Access Router 2 Ports –
Capable
Access Router single port
Not capable
Dynamic Routing --
Capable
Primary
Parameters
Parameter—Options;
Definition
Default
NET Alarms
Block All Alarms
—Yes, No
Yes—Blocks the reporting of all alarms.
No—Enables the unit to report alarms.
No
Carrier Loss Alarm
—Enabled, Disabled
Enabled—The unit generates an alarm when a network carrier Loss of
Signal is detected on the network.
Disabled—Disables the alarm.
Sync Loss Alarm
—Enabled, Disabled
Enabled—The unit generates an alarm when loss-of-frame is detected on
the network.
Disabled—Disables the alarm.
Enabled
Enabled
Parameter
Description