STEP 1. Mount armature to door. (See figures
2A, 2B & 2C.)

STEP 2.

Install the mounting plate (filler plate

and/or angle bracket if needed – see figures 1A,
1B &

1C)

to header with only the two screws at

the slotted hole locations at this time. Snug the
screws down lightly (do not torque) so the
mounting plate & lock can be repositioned later.

STEP 3. Temporarily install the lock to the
mounting plate with the 1/4-20 socket head
screws encased in the lock.

STEP 4. With the lock mounted, close the door
so the armature just comes into contact with the
face of the lock. If the door is not completely
closed as the lock & armature touch, open the
door and reposition the lock away from the door
as described in step 2.

(THIS IS TO PREVENT

THE DOOR FROM USING THE LOCK AS THE
DOOR STOP.)

STEP 5. Remove the lock from the mounting
plate, mark & punch all remaining screw and
wiring holes. Drill & tap holes as indicated on the
paper template and install all screws.

STEP 6.

Reinstall the lock to the mounting

plate. At this point, if there is no need to remove
the lock for painting or any other reason, install
the anti-tamper plugs over the socket head
mounting screws, using a soft hammer to avoid
damage to the lock case.

ARMATURE MOUNTING INSTRUCTIONS

Figure 2B – HOLLOW METAL DOOR

From sexnut side of door, drill exactly 1/2" hole through one metal thickness

only. From armature side of door, drill 5/8" hole to insert reinforcement tube.

Press in sexnut & reinforcement tube all the way and mount armature to door

using hardware provided per Figure 2B.

Figure 2A – SOLID DOOR

Drill exactly 3/8" through the door. From sexnut side of door, drill ½”

diameter hole 1-3/8" deep. Mount armature to door with hardware

provided per Figure 2A.

Figure 2C – REINFORCED ALUMINUM OR

HOLLOW METAL DOOR

Use letter “F” drill and tap for 5/16-18 machine screw. Mount

armature to door with hardware provided per Figure 2C.

REGULAR, FILLER PLATE & ANGLE BRACKET DETAILS

Figure 1A

REGULAR

Figure 1B

WITH FILLER PLATE

FILLER PLATE

Figure 1C

WITH ANGLE BRACKET

ANGLE BRACKET

P:\INSTALLATION INST\Delayed Egress\INST-1581S\INST-1581S.vsd REV D7 03-13 Page 5

ARMATURE HOLDER

ARMATURE

DOOR

REINFORCEMENT

BY OTHERS

LETTER “F”

DRILL & TAP 5/16-18

5/16-18 SOC HD
SCREW
WITH 3/16 (5MM)
ALLEN HEX

5/8" DRILL

ARMATURE HOLDER

ARMATURE

1/2" DRILL

REINFORCEMENT TUBE

1 – ¾” HOLLOW

METAL DOOR

5/16-18 SOC HD
SCREW
WITH 3/16 (5MM)
ALLEN HEX

ARMATURE HOLDER

ARMATURE

1/2”

SEX NUT

21/64" DRILL

DOOR

1–3/8"

5/16-18 SOC HD
SCREW
WITH 3/16 (5MM)
ALLEN HEX