Included in package, Suggested optional equipment, Station controls, annunciator panels, and consoles – SDC 1581S MINI EXIT CHECK DELAYED EGRESS EMLOCK User Manual
Page 3: 1581s specifications
Included in Package
ARMATURE
SCREW PACK
1580S-101-C
728U
Single station two
function key switch
control for alarm
reset and access or
sustained bypass.
101-4AM
Provides visual &
audible annunciation
with audible mute for
up to four openings.
728UL3
Single station two
function key switch
control for alarm reset
and access with a tri-
colored LED showing
door condition.
702RU
Single station one
function key switch
control for alarm reset.
101-1A
The single station
annunciator is
equipped with a tri-
colored LED and
audible alarm.
101-1AK
Visual & audible
annunciation and a
two function key
switch for alarm reset
and access or
sustained bypass.
101-PAM
Visual & audible
annunciation, timed
access, sustained
bypass and audible
mute.
SDC Annunciator Consoles
provide remote annunciation
of multiple openings. Stations
are specified in sets of four.
Control switches are capable
of both sustained bypass and
timed unlocking.
TCC Desk Top :
Stations 4, 8, & 12
Suggested Optional Equipment
Power Supply
Station Controls, Annunciator Panels, and Consoles
P:\INSTALLATION INST\Delayed Egress\INST-1581S\INST-1581S.vsd REV D7 03-13 Page 3
600 Series Power Supply
Field Selectable 12 or 24VDC modular
Power Supplies with Fire/Life Safety
Emergency Release. Tri-colored LED,
separate PTC protected battery charger,
and Class 2 Outputs.
602RF 1 Amp
631RF 1.5 Amp
632RF 2 Amp
634RF 4 Amp
636RF 6 Amp
PSB560
Request-to-exit touch
sense non-latching bar
that will activate the
Exit Check
®
when
slight pressure is
applied to the bar. For
doors without latching.
1581S Specifications
Interior Applications Only
Size: 10"L x 2-1/8"H x 2-3/8"D
Power/Current Requirements:
- 320 mA @ 24VDC
- 500 mA @ 12VDC
Lock Status Relay Rating: 1 amp @ 30V resistive
DPS Rating: 250 mA @ 30V resistive
BAS Option: Internal
(NOTE: The BAS option works in conjunction with the
lock status relay. It does not have a separate output.)
ARMATURE PLATE
1581S-10T
EMLOCK
SCREW PACK
C-1500-RF
TEMPLATE
TEMP-1581S
CONTROLLER
CABLE ASSEMBLY
CA-1581S
1581S EMLOCK
HOUSING ASSY. &
MOUNTING PLATE
TRIGGER BLOCK
ASSY 1580S-11
918 Digital Keypad
Two relay outputs:
Relay 1 -Reset;
Relay 2 – Choice of
momentary or
sustained bypass.
Digital Entry
Note:
A key switch, keypad, or push button
(see models below) MUST be provided
and purchased separately to operate the
Reset and Rex Functions.