Door and frame reference dimensions, Door and frame preparation instructions – SDC 1581S MINI EXIT CHECK DELAYED EGRESS EMLOCK User Manual
Page 4
NOTES:
- #10 self drill/tap screws provided for up to ⅛" thick metal applications
- For applications with heavier gauge material, drill (#21) and tap for #10-32 machine screws.
Door and Frame reference dimensions
IMPORTANT! – IT IS HIGHLY RECOMMENDED THAT YOU FIRST INSTALL THE MOUNTING PLATE AT TWO SLOT LOCATIONS ONLY.
THIS WILL ALLOW YOU TO MAKE PROPER ADJUSTMENTS OF THE LOCK’S POSITION PRIOR TO MARKING, DRILLING AND TAPPING
THE FOUR PERMANENT MOUNTING PLATE HOLES.
Door and Frame Preparation Instructions
HINGE SIDE OF FRAME
(OPPOSITE FROM LOCK)
PAPER TEMPLATE
STEP 1. Locate the paper template and fold
along the dotted line. Place the folded edge of
the template against the door stop and door at
the header while against the vertical stop,
opposite the hinge side of the door. Tape in
place at this position.
STEP 2.
As indicated on the paper template,
punch the designated hole locations on the
frame and armature mounting holes on the door.
(NOTE: PRIOR TO DRILLING, INSPECT TO SEE IF
ANY OF THE HOLES CANNOT BE DRILLED DUE
TO THE FRAME OR DOOR CONFIGURATION. A
FILLER PLATE OR ANGLE BRACKET MAY BE
REQUIRED. SEE PAGE 5.)
STEP 3.
Drill and tap the two 1581S mounting
holes as indicated on the paper template.
(NOTE: READ NOTE ON TEMPLATE WITH
REGARD TO SELECTING THE PROPER HOLE
SIZE FOR ARMATURE MOUNTING BOLT.)
1 ⅞"
2 ⅜"
9
15
/
16
"
2 ⅛"
P:\INSTALLATION INST\Delayed Egress\INST-1581S\INST-1581S.vsd REV D7 03-13 Page 4
SLOT LOCATIONS
PLACE AGAINST DOOR
PLACE AGAINST
DOOR JAMB
FOR R.H. DOOR
PLACE AGAINST
DOOR JAMB
FOR L.H. DOOR
DRILL ¼” DIAMETER HOLE X
9
/
16
" DEEP
CENTER PUNCH ON
MARK & REFER TO
INSTRUCTION SHEET
FOR HOLE SIZE.
PLACE AGAINST HEADER
½” DIA. HOLE
Mark location four places.
FOLD ON DOTTED LINE
05/04
DWG #4770
TEMP-1581S
1
3
/
16
”
1 ½”
SLOT LOCATIONS