Privacy mode/secretary mode, Disable/enable three strike lockout, Battery check status – SDC E72K-A CIVIC SERIES 160 User Electronic Digital Door Lock User Manual
Page 5
P:\INSTALLATION INST\ELECTRIFIED LOCKSETS/INST-E72K-A/INST-E72K-A.vsd REV -
07-08 Page 5
PRIVACY MODE/SECRETARY MODE
An E72K-A with the Privacy Mode option (Secretary Mode is default) will have a button installed on the inside housing. When the button
is pressed it will block out keypad entries (except User Codes from groups 01-03). When the inside lever is pressed the request to exit
switch will reset the keypad back to normal operating mode.
Enter MASTER CODE
#
PRIVACY MODE
*
39
*
*
1
Enter MASTER CODE
#
SECRETARY MODE
*
39
*
*
0
DISABLE/ENABLE THREE STRIKE LOCKOUT
The lock responds to three consecutive incorrect codes by displaying a red light and shutting down the keypad for 20 seconds. Subsequent
attempts with an incorrect code will increase the time to 40 seconds maximum. Disabling this feature allows an unlimited number of
incorrect codes to be entered without a lockout.
Enter MASTER CODE
#
DISABLE
*
40
*
*
0
Enter MASTER CODE
#
ENABLE
*
40
*
*
1
CLEAR MEMORY
If it becomes necessary to clear the memory of the E72K-A, there are two options other than the “Full Reset” option.
Enter MASTER CODE
#
DELETE ALL USERS AND SCHEDULES
*
16
*
16
*
*
0
Enter MASTER CODE
#
DELETE ONLY SCHEDULES
*
16
*
16
*
*
1
This function manually checks the battery status of E72K-A. The LED on the keypad will display visual indicator.
BATTERY CHECK STATUS
Enter MASTER CODE
#
*
17
*
Watch LED
Green – Green:
Two green LED flashes indicate full power 5.25 volts and above.
Yellow – Yellow:Two yellow LED flashed indicate 5.25 to 4.75 volts.
Yellow – Red:
Yellow then red LED flashes indicate 4.75 to 4.37 volts.
Red -Red:
Two red flashes indicate below 4.37 volts. Batteries need to be changed.
NOTE: IF THE VOLTAGE OF THE BATTERIES FALLS TO 4.2v DC, THE
E72K-A WILL BEEP EVERY HOUR INDICATING LOW BATTERY STATUS.