SDC E72K-A CIVIC SERIES 160 User Electronic Digital Door Lock User Manual
Page 3
P:\INSTALLATION INST\ELECTRIFIED LOCKSETS/INST-E72K-A/INST-E72K-A.vsd REV -
07-08 Page 3
PIN ONLY ENTRY
The PIN only mode will shorten the code required to open the lock.
Enter MASTER CODE
#
ENABLE (PIN TO OPEN LOCK)
*
32
*
*
*
0
This function gives the users the ability to change their PIN (user must know their User ID & PIN to perform this function).
CHANGE USER PIN
Enter MASTER CODE
#
(Verify PIN)
* *
*
*
08
(New PIN)
DEFINE OPEN TIME
This function will adjust the amount of time the lock will stay unlocked after a valid User code has been entered.
The open time can be set from 1 to 9 seconds (default setting is 3 seconds).
Enter MASTER CODE
#
*
*
*
18
Single digit 1 – 9 Seconds
LOCK AUDIO
When the audio is set to “ON” the lock will beep with each key pressed (ON by default).
Enter MASTER CODE
#
AUDIO OFF
*
34
*
*
0
Enter MASTER CODE
#
AUDIO ON
*
34
*
*
1
TERMINATOR ON/OFF
This function will switch the Terminator On or Off. Selecting off automatically sets lock to PIN Only mode. To gain access with
Terminator Off, simply enter your PIN code. With Terminator On, you are required to enter after your code.
Enter MASTER CODE
#
TERMINATOR OFF
*
37
*
*
0
Enter MASTER CODE
#
TERMINATOR ON
*
37
*
*
1
NOTE: TO ENTER PROGRAM MODE WITH TERMINATOR OFF, YOU MUST FIRST PRESS THE “#” KEY BEFORE THE MASTER CODE.
Enter MASTER CODE
#
DISABLE (USER ID & PIN TO OPEN LOCK)
*
32
*
*
*
1
*
*