TROUBLE SHOOTING
 
SYMPTOM 
PROBLEM
SOLUTION
REF.
Air conditioning not 
cooling. (continued) 
Loose or broken drive 
belt. 
Replace drive belt and/ 
or tighten to specs. 
66
Compressor partially or 
completely seized. 
Remove compressor for 
service or replacement. 
*
Dirty filters.
Clean fresh air and re-
circulation filters. 
107, 108
Broken or disconnected 
electrical wire. 
Check all terminals for 
loose connections; 
check wiring for hidden 
breaks. 
---
Broken or disconnected 
ground wire. 
Check ground wire to 
see if loose, broken, or 
disconnected. 
---
Expansion valve stuck 
in open or closed 
position. 
Replace expansion 
valve. 
*
Broken refrigerant line.
Examine all lines for 
evidence of breakage 
by external stress or 
rubbing wear. 
*
Leak in system.
Leak-test system; repair 
leaks as necessary. 
*
Compressor shaft seal 
leaking. 
Replace compressor 
shaft seal. 
*
Clogged screen in 
receiver-drier; plugged 
hose or coil. 
Repair as necessary. 
Replace receiver-drier; 
evacuate and charge. 
*
Air conditioning not 
producing sufficient 
cooling. (Sufficient 
cooling defined as when 
air temperature in cab, 
measured at louvered 
vent, can be maintained 
at 25
°F (14°C) below
ambient air 
temperature.) 
Compressor clutch 
slipping. 
 
 
Clogged air filter. 
 
 
 
Heater circuit is open. 
 
Too little air circulation 
over condenser coil; fins 
clogged with dirt or 
insects. 
Remove clutch 
assembly for service or 
replacement. 
 
Remove air filter and 
clean or replace as 
necessary. 
 
Close heater valves 
(1 in cab, 1 at engine). 
Clean condenser. 
* 
 
 
 
107 
 
 
 
21 
 
78 
Evaporator fins clogged.
Clean evaporator fins 
(under seat) 
108
 
 
Too little refrigerant in 
system. 
Recharge system until 
gauge readings stabilize 
to specifications. 
109