MacDon M150 SP User Manual
Page 234
M150 AND M200 ENGINE ERROR CODES
Form # 169017 / 169087 / 169095
232
Revision C
J1939 SPN
Description
J1939
SPN
J1939
FMI
Lamp
Color
Cummins
Engine
Code
CAT
Engine
Code
Cummins / Caterpillar Description
4 Amber 2374
Exhaust Gas Pressure Sensor Circuit - Voltage Below Normal, or
Shorted to Low Source
Fuel Pump
Pressurizing
Assembly #1
1347
3
Amber
272
High Fuel Pressure Solenoid Valve Circuit - Voltage Above Normal,
or Shorted to High Source
4
Amber
271
High Fuel Pressure Solenoid Valve Circuit - Voltage Below Normal,
or Shorted to Low Source
5 162
1779
Output current low
6 162
1779
Output current high
7
Amber
281
1779
High Fuel Pressure Solenoid Valve #1 - Mechanical System Not
Responding Properly or Out of Adjustment
Engine Oil
Change
Interval
1378
31
Maint
649
Change Lubricating Oil and Filter - Condition Exists
Auxiliary
Pressure
1388
3
Amber
297
Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Above
Normal, or Shorted to High Source
4
Amber
298
Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Below Normal,
or Shorted to Low Source
14
Red
296
Auxiliary Pressure Sensor Input 1 - Special Instructions
J1939 Error
1484
31
None
211
Additional Auxiliary Diagnostic Codes logged - Condition Exists
Control
Module
Identification
Input State
1563
2
Amber
1256
Control Module Identification Input State Error - Data Erratic,
Intermittent, or Incorrect
Accelerator
Pedal Position
2623
3
Amber
1239
Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage
Above Normal, or Shorted to High Source
4
Amber
1241
Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage
Below Normal, or Shorted to Low Source
System
Diagnostic
Code #1
2629
15
None
2347
Turbocharger Compressor Outlet Temperature (Calculated) - Data
Valid but Above Normal Operational Range - Least Severe Level
System
Diagnostic
Code #1
2789
15
None
2346
Turbocharger Turbine Inlet Temperature (Calculated) - Data Valid
but Above Normal Operational Range - Least Severe Level
Coolant
Pressure
2981
3
Amber
2115
Coolant Pressure 2 Circuit - Voltage Above Normal, or Shorted to
High Source
4
Amber
2116
Coolant Pressure 2 Circuit -Voltage Below Normal, or Shorted to
Low Source
18
Amber
2117
Coolant Pressure 2 - Data Valid but Below Normal Operational
Range - Moderately Severe Level
System
Diagnostic
Code # 1
3511
4
Amber
238
Sensor Supply Voltage #3 Circuit - Voltage Below Normal, or
Shorted to Low Source
3 Amber 239
Sensor Supply Voltage #3 Circuit - Voltage Above Normal, or
Shorted to High Source