MAINTENANCE AND SERVICING - M200 ENGINE
Form 169017 / 169087 / 169095
170
Revision C
7.9.8 GEARBOX
7.9.8.1 Lubricant
Level
CAUTION
Park on a flat, level surface, header on the
ground and the ground speed lever in N-
DETENT position.
DANGER
Stop engine and remove key from ignition
before leaving Operator’s seat for any reason.
A child or even a pet could engage an idling
machine.
a. Check the lubricant level every 50 hours, or
weekly as follows:
1. Park the windrower on level ground, shutdown
the engine, and remove the key.
2. Remove plug (A). The lubricant should be
visible through the hole or slightly running out.
b. Add lubricant as follows:
1. Raise engine compartment hood to highest
position.
2. Remove breather cap (B), and add lubricant
until it runs out at (A). Use SAE 75W-90 API
Service Class GL-5, Fully Synthetic
Transmission Lubricant. SAE J2360
preferred.
3. Replace plug (A) and breather cap (B), and
tighten.
B