3 technical data, 1 general data and operating conditions, Technical data – Lenze EVF9338 User Manual
Page 69: General data and operating conditions, 3technical data

Technical data
General data and operating conditions
3
l
69
EDKVF9338 DE/EN/FR 4.0
3
Technical data
3.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
Protection of persons and equipment
Type of protection
EN 60529
IP20
NEMA 250
Protection against accidental contact according to type 1
Earth leakage current
IEC/EN 61800−5−1
> 3.5 mA
Observe stipulations and safety
instructions!
Insulation of control
circuits
IEC/EN 61800−5−1
Safe mains isolation by double (reinforced) insulation for the
terminals X1 and X5.
Basic insulation (single isolating distance) for the terminals
X3, X4, X6, X8, X9, X10 and X11.
Insulation resistance
IEC/EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Protective measures
Against short circuit, earth fault (earth−fault protected during
operation, limited earth−fault protection during mains
power−up), overvoltage, motor stalling, motor
overtemperature (input for PTC or thermal contact)
EMC
Noise emission
EN 61800−3
Cable−guided, up to 50 m motor cable length with RFI filter:
Category C2.
Radiation, with RFI filter and installation in control cabinet:
Category C2
Interference immunity
IEC/EN 61800−3
Category C3