C14893 | process data length, C14894 | baud rate, C14900 | firmware product type – Lenze E94AYCIB User Manual
Page 69: C14893, C14894, C14900, 13 parameter reference
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
69
13
Parameter reference
13.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14893
C14894
C14900
Parameter | Name:
C14893 | Process data length
Data type: UNSIGNED_8
Index: 9682 = 0x25D2
Setting of the number of the process data words to be used
The setting is activated ...
• if all DIP switches (S205) are in the "OFF" position;
• after executing the "11: Save start parameters" device command via standard device code C00002 and
performing another mains switching of the communication module/drive afterwards.
Setting the number of process data words ( 31)
Selection list
(Lenze setting printed in bold)
Info
0 No process data
1 1 word
2 2 words
3 3 words
4 4 words
5 5 words
6 6 words
7 7 words
8 8 words
9 9 words
10 10 words
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14894 | Baud rate
Data type: UNSIGNED_8
Index: 9681 = 0x25D1
setting the baud rate
The setting is activated ...
• if all DIP switches (S205) are in the "OFF" position;
• after executing the "11: Save start parameters" device command via standard device code C00002 and
performing another mains switching of the communication module/drive afterwards.
Selection list
(Lenze setting printed in bold)
Info
0 500 kbps
1 2.00 Mbps
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14900 | Firmware product type
Data type: VISIBLE_STRING
Index: 9675 = 0x25CB
Display of the product type (string with a length of 8 bytes)
• The following identification code is displayed: "E94AFCIB".
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT