Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
19
4
Technical data
4.4
Protective insulation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Example
Which type of protective insulation is used between the bus terminal of the device module in slot
MXI1 or MXI2 and the mains terminal X100?
The separate potential area with the better protective insulation is decisive.
• The separate potential area of the bus terminal of the device module has a "functional
insulation".
• The separate potential area of the mains terminal has a "reinforced insulation".
Result: The insulation between mains terminal X100 and the bus terminal is of the "reinforced
insulation" type.
Terminal strip Connection
Terminal strip Connection
X100 L1, L2, L3 (Single Drive only)
X1 CAN on board 9400
+UG, -UG
X2 State bus
X105 U, V, W
24 V (ext.)
Rb1, Rb2 (Single Drive only)
X3 Analog inputs/outputs
X106 Motor PTC
X4 Digital outputs
X107 Control of the motor holding
brake
X5 Digital inputs
X6 Diagnostics
X7 Resolver
X8 Encoder
MXI1, MXI2 Extension module
MMI Memory module
MSI Safety module
X205 External voltage supply (24 V DC)
X206 INTERBUS connection, input (IN)
X207 INTERBUS connection, output
(OUT)