Interbus: internal error [0x00c86101, Interbus: internal mapping error [0x00c86110, Interbus: invalid parameter set [0x00c8641f – Lenze E94AYCIB User Manual
Page 51: Interbus: lenze setting loaded [0x00c86420, Interbus: invalid configuration [0x00c88125, 0x00c86101, 0x00c86110, 0x00c8641f, 0x00c86420, 0x00c88125

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
51
12
Error messages
12.2
Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
INTERBUS: Internal error [0x00c86101]
INTERBUS: Internal mapping error [0x00c86110]
INTERBUS: Invalid parameter set [0x00c8641f]
INTERBUS: Lenze setting loaded [0x00c86420]
INTERBUS: Invalid configuration [0x00c88125]
INTERBUS: Reset of the communication stack [0x00c88126]
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
Send module with error description to Lenze.
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The selected PDO mapping is invalid:
• An object not supporting the required properties has
been specified.
• The data word sum (process data words + parameter
data words) has to consist of 1 ... 10 words (16 bits/
word).
Repeat
Configuring process data (PDO mapping) ( 37)
.
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
No active parameter set could be loaded.
Download application again (including module).
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Access via standard device to the parameter set in the
memory module failed.
Download application again (including module).
Response (Lenze setting printed in bold)
Setting: not possible
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The active configuration is invalid:
• Process data words + parameter data words > 10
• Process data words + parameter data words = 0
The data word sum (process data words + parameter
data words) has to consist of 1 ... 10 words (16 bits/
word).
Adapt the number of process data words and parameter
data words:
• Process data words + parameter data words = 1 ... 10
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked warning Information
Cause
Remedy
Error when processing the INTERBUS services
Execute renewed initialisation by the master.