Parameter data transfer
9.3
Supported PMS services
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.3
Supported PMS services
The parameter data is transferred via PMS services.
In the following, only parameters and their contents are given that are returned by the Lenze
inverters. All other transfer parameters of the given PMS services can be obtained from the
corresponding descriptions of the INTERBUS master.
The following PMS services are supported by Lenze inverters:
• Initiate: Establish a connection of the INTERBUS master to the inverter
• Abort: Abort connection
• Reject: Reject impermissible PMS service
• Read: Read parameters
• Write: Write parameters
• Get-OD: Read out the object directory
• Identify: Identification of the inverter
• Status: Read the status of the inverter
9.3.1
Initiate
The "Initiate" PMS service establishes a logic connection between the INTERBUS master and the
communication module.
The inverter provides the following parameters:
9.3.2
Abort
The "Abort" PMS service aborts a logic connection between the INTERBUS master and the
communication module.
9.3.3
Reject
The "Reject" PMS service rejects a non-supported PMS service.
Name
Value
Description
Profile number
0
No profile is supported.
Password
0
The password function of INTERBUS is not supported.
Access groups
0
No access groups exist.
Access-Protection Supported
TRUE
Access protection is supported.
Version OD
0
Version of the object directory