C13901 | firmware compilation date, C13902 | firmware version, C13920 | display of dip switch position – Lenze E94AYCIB User Manual
Page 62: C13902, 13 parameter reference
13
Parameter reference
13.2
Parameters of the communication module for slot MXI1
62
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13901
C13902
C13920
Parameter | Name:
C13901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 10674 = 0x29B2
Display of the compilation date of the firmware (string with a length of 20 bytes)
• The date ("MMM TT JJJJ") and the time ("hh:mm:ss") are output, e.g. "Mar 21 2005 12:31:21".
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673 = 0x29B1
Display of the firmware version (string with a length of 8 bytes)
The identification code is output, e.g. "01.00.00".
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13920 | Display of DIP switch position
Data type: BITFIELD_8
Index: 10655 = 0x299F
Display of the current DIP switch position
• The set parameter data length (PCP) is displayed in
.
• The set process data length is displayed in
• The set baud rate is displayed in
.
Possible settings via DIP switch ( 30)
Value is bit-coded:
Info
Bit 0 DIP 8
Baud rate
Bit 1 DIP 7
No response
Bit 2 DIP 6
Number of parameter data words (PCP)
Bit 3 DIP 5
Bit 4 DIP 4
Number of process data words
Bit 5 DIP 3
Bit 6 DIP 2
Bit 7 DIP 1
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT