Installation, 4 nema 4x (ip65) models with disconnect switch – Lenze ESV SMV frequency inverter User Manual
Page 17

Lenze SMVector 13465100 EDBSV01 EN v18
15
Installation
3.1.4
NEMA 4X (IP65) Models with Disconnect Switch
b2
b
b1
a
a1
c
c1
s1
s2
s2
s1
Mounting Screws
4 x #8-32
10 lb-in
4 x M4
1.2 Nm
(
)
Type
a
in
(mm)
a1
in
(mm)
b
in
(mm)
b1
in
(mm)
b2
in
(mm)
c
in
(mm)
c1
in
(mm)
s1
in
(mm)
s2
in
(mm)
m
lb
(kg)
AA1
ESV371N01SM_; ESV371N02YM_;
ESV371N02SL_; ESV371N04TM_;
ESV371N04TL_; ESV371N06TM_;
ESV751N01SM_; ESV751N02YM_;
ESV751N02SL_; ESV751N04TM_;
ESV751N04TL_; ESV751N06TM_;
6.28
(160)
5.90
(150)
10.99
(279)
9.54
(242)
0.66
(17)
4.47
(114)
.86
(22)
2.00
(51)
2.00
(51)
4.7
(2.13)
AA2
ESV112N01SM_; ESV112N02YM_;
ESV112N02SL_; ESV112N04TM_;
ESV112N04TL_; ESV152N02YM_;
ESV152N02SL_; ESV152N04TM_;
ESV152N04TL_; ESV152N06TM_;
ESV222N04TM_; ESV222N04TL_;
ESV222N06TM_; ESV302N04TL_;
6.28
(160)
5.90
(150)
10.99
(279)
9.54
(242)
0.66
(17)
6.31
(160)
.86
(22)
2.00
(51)
2.00
(51)
7.9
(3.58)
AD1 ESV222N02SL_; ESV222N02YM_;
7.12
(181)
6.74
(171)
10.99
(279)
9.54
(242)
0.66
(17)
6.77
(172)
.86
(22)
2.00
(51)
2.00
(51)
9.0
(4.08)
AB1
ESV552N02TM~; ESV752N02TM~
ESV752N04TM~; ESV752N06TM~;
ESV752N04TL~
8.04
(204)
7.56
(192)
13.00
(330)
11.04
(280)
0.92
(23)
8.00
(203)
.86
(22)
4.00
(102)
4.00
(102)
13.9
(6.32)
AC1
ESV402N02TM_; ESV402N04TM_;
ESV552N04TM_; ESV402N06TM_;
ESV552N06TM_; ESV402N04TL_;
ESV552N04TL_
8.96
(228)
8.48
(215)
13.00
(330)
11.04
(280)
0.92
(23)
8.04
204)
.86
(22)
4.00
(102)
4.00
(102)
14.7
(6.66)
AE1
ESV113N04TM~; ESV153N04TM~,
ESV113N06TM~; ESV153N06TM~
9.42
(240)
8.94
(228)
14.50
(368)
12.54
(319)
0.92
(24)
9.45
(241)
0.73
(19)
4.00
(102)
4.00
(102)
23.0
(10.4)
AF1
ESV113N02TM~; ESV153N02TM~
ESV113N04TL~; ESV153N04TL~
ESV183N04TL~; ESV223N04TL~
ESV183N04TM~; ESV223N04TM~
ESV183N06TM~; ESV223N06TM~
9.42
(240)
8.94
(228)
18.5
(470)
16.54
(420)
0.92
(24)
9.45
(241)
0.73
(19)
4.00
(102)
4.00
(102)
28.5
(12.9)
_ = Last digit of part number:
C = N4X Indoor (convection cooled)
~ = Last digit of part number: D = N4X Indoor (fan cooled)
Conduit Hole Dimensions
Type
N
in (mm)
P
in (mm)
Q
in (mm)
S
in (mm)
S1
in (mm)
Q
Q
P
N
S
S
S1
P
Q
Q
N
AA1
3.14 (80)
2.33 (59)
1.50 (38)
.88 (22)
n/a
AA2
3.14 (80)
4.18 (106)
1.50 (38)
.88 (22)
n/a
AD1
3.56 (90)
4.63 (118)
1.50 (38)
.88 (22)
n/a
AB1
4.02 (102)
5.00 (127)
1.85 (47)
1.06 (27)
n/a
AC1
4.48 (114)
5.00 (127)
1.85 (47)
1.06 (27)
n/a
AE1
4.71 (120)
5.70 (145)
2.00 (51)
1.375 (35)
1.125 (28)
AF1
4.71 (120)
5.70 (145)
2.00 (51)
1.375 (35)
1.125 (28)