beautypg.com

Multiserver 5000, 5 network security – Black Box 5000 User Manual

Page 146

background image

Multiserver 5000

144

11.5 Network Security

Protecting selected portions of the Command Mode
and the Command Facility involves two types of
security: password protection and lock-out
configuration.

P

ASSWORDS

Passwords are security protection for the
Multiserver. Four types of password protection can
be assigned to the Multiserver unit: Command
Facility, Channel, Class, and LCD/Keypad. Channel
and Class passwords can be displayed from the
Command Facility. Command Facility and
LCD/Keypad passwords are not recorded for
display anywhere. (If the Command Facility or
LCD/Keypad password is forgotten, a cold start is
required. A cold start returns the Multiserver to
factory defaults, thus erasing all configurations
done by the system manager or individual users.)

Password Syntax:

Valid global and status
passwords must use upper
case alpha-numeric (A to Z, 0
to 9) characters, with a
maximum length of eight
characters.

NULL Passwords:

By factory default, all
passwords are NULL (no)
passwords. If a password is
currently configured and is
no longer required, enter a
space at the password
prompt. Press .

Channel Passwords

are configured in the Async

Switching Parameters menu (as option 9). For
information on configuring channel passwords, see
Section 10.7, Asynchronous Channel Switching
Parameters

, and Table 10-2. To view channel

passwords, access Async Channel Switching
Parameters in the View Configuration menu. See
Section 10.12, Review Switching Configuration for
an Async Channel, for

detailed information on this

procedure.

Class passwords

are configured in the Class

Parameters Menu, as option 3. For information on
configuring class passwords, see Section 10.8,

Classes

, and Table 10-3. To view the class passwords,

enter the Review Configuration menu and choose
option 5 (classes). Information on reviewing class
passwords is also found in Section 10.8, Classes.

Command Facility Passwords

and the LCD/Keypad

Password

are configured through the Passwords

menu, which is option 12 of the Configure Local
Nodes menu.

The three menu options are detailed in
Table 11-6

, which is on the next page.

COMMAND FACILITY MAIN MENU [node id]

CONFIGURE LOCAL NODES

3

CONFIGURE LOCAL NODES [node id]

PASSWORDS

12

PASSWORD

1. GLOBAL (ALLOWS ANY

COMMAND OR TEST)

2. STATUS (VIEW,STATUS ONLY)

3. LCD/KEYPAD

CR - ACCEPT ENTRY

M - MAIN MENU

ENTRY: