HYDAC CSI-F-10 User Manual
Page 73

GSM Radio Module CSI-F-10
Page 73
Status 29.01.2009
HYDAC ELECTRONIC GMBH
Part.-Nr.:
669752
• You can transfer the currently opened CM program to the CSI-F-10 with
"Transfer into device“.
Note!
Only error-free programs can be transferred into the CSI-F-10.
The following message appears after the program has been successfully
transferred:
Here you can select whether you also wish to transfer the source code of the
program into the CSI-F-10.
Note!
If the source code is also transferred into the CSI-F-10, then it is possible for it
to be read again by every other connected PC and modified! If the source
code is not also transferred into the CSI-F-10, then the program cannot be
uploaded by another PC.
The following message will appear if the CM program contains errors when
attempting transfer:
Eliminate the error(s) found in the CM program (see Chap. 8.2.2 "Function list“
window and Chap. 10. "Error messages“) and transfer the program again.
Note!
If you transfer a program and a power failure occurs during the transfer, then
the program will not be saved in the CSI-F-10 after power is restored. For that
reason, first save your program on the PC on which it was originally generated
or modified before making the transfer.