6.3.1 Device Connection
• Connect the RS232 serial interface of your PC with the 9-pin SUB-D socket of
the HYDAC interface module CSI-B-2 via a corresponding data cable (or
RS485 via terminal block).
• Connect the CSI-F-10 to the CSI-B-2 via the HSI connection
-X2 / Pin 3 and 4 on the CSI-B-2
Connection B / Pin 4 and 5 on ZBE 26 on the CSI-F-10
• Connect the voltage supply to the CSI-F-10 GSM radio module according to the
diagram.
10,5..35 V D C
H SI
+U
B
G N D
Supply
voltage
RS232
(USB via
appropriate
adaptor)
A
ZBE 26
B
18..35 V DC
+U
B