Reload firmware, Reset to defaults, N o t e – ETC Unison Paradigm Touchscreen User Manual
Page 22
20
Unison Paradigm Touchscreen User Manual
•
Firmware: the Touchscreen co-processor firmware version.
Reload Firmware
The [Reload Firmware] button is provided as a tool to load new firmware. Firmware is
loaded to the Touchscreen from removable media.
Step 1:
Insert the USB key or SD card, with the firmware files saved, into the port on the
Touchscreen.
Step 2:
Press the [Reload Firmware] button.
Step 3:
Select the removable media (USB or SD) from the recognized installed media.
Step 4:
Select the “firmware.pts” file from the list. As the firmware file completes loading,
the Touchscreen will reboot.
Reset to Defaults
Restores factory defaults to the settings on the “Screen”, “Sound”, and “Network” pages.
N o t e :
The Touchscreen firmware file is stored in the LightDesigner installation directory
firmware folder (the file is titled “firmware.pts”). Save the file to the root directory
of a USB or SD card for loading onto the Paradigm Touchscreen.
N o t e :
A message may display when the firmware file is not recognized on the selected
removable media. Check that the firmware file was saved to the root directory of
the selected media, then try the reload process again.
N o t e :
When updating your Touchscreen firmware, you may also need to update your
Paradigm Architectural Control Processor firmware to remain compatible.