Unison Paradigm Touchscreen User Manual

If the sensor registers any moving or stationary objects within this range, it will
“wake” the station from its sleeping state and reset the backlight timeout and the
station inactivity timer as set in ControlDesigner.

Calibrate Touchscreen

The “Screen” tab provides a [Calibrate Touchscreen] button that will launch the

calibration display. This display is provided as a tool for recalibration of the Touchscreen.

Calibration may be required if presses on the Touchscreen are recognized in an area other

than where the screen was pressed.

To calibrate the Touchscreen, simply touch as close to the center of the “+” symbol as it is

displayed. The “+” symbol will move to five separate coordinates on the touchscreen to

complete the calibration.

When all five coordinates have been calibrated, press [Close] to return to the previously

displayed page. If you are unsatisfied with the calibration results, press [Recalibrate] to

start the calibration again or press [Clear] to clear your settings.

N o t e :

Be aware of stationary objects (such as rack doors) that remain within the sensing

range as it may interfere with the function of the sensor. In these applications, it is

best practice to disable the Proximity Sensor.
The proximity sensor is looking for reflected IR; therefore any IR devices (such as

alarms or listening assistance systems) within a range of the proximity sensor may

prevent the system from sleeping or displaying an inactivity page.

N o t e :

Alternatively, press and hold the [Mode] button (located on the I/O panel of the

Touchscreen) for four seconds to launch the calibration display.