beautypg.com

Setup menu, About tab, N o t e – ETC Unison Paradigm Touchscreen User Manual

Page 10

background image

8

Unison Paradigm Touchscreen User Manual

Setup Menu

Pressing the [Setup] button on the default page displays the

About tab

of the Touchscreen

setup menu. Alternatively, you can access the setup menu by pressing the “Mode” pin on

the Touchscreen I/O panel.

See “Touchscreen Inputs, Outputs and Indicators” on page 4.

Each tab of the setup menu displays a footer of buttons including [Service Pin], [Ok] and

[Cancel].

About tab

The About tab displays read-only information pertaining to the Touchscreen including;

MAC Address: a unique identifier assigned to the Touchscreen by ETC for
identification over the Paradigm network.

IP Address: the current network IP address assigned to the Touchscreen. This number
can be modified from the

Network tab

.

Neuron Id: a station specific unique hardware address that is permanent to the
Touchscreen. This ID is used by the Paradigm Architectural Control Processor to bind/
associate (bind) stations within the LightDesigner configuration.

Bootloader: the bootloader software version.

Firmware: the firmware version loaded onto the Touchscreen. Firmware can be
updated, reference

System tab, page 19

for instructions.

Memory Usage: a Paradigm Touchscreen has 128 megabytes (Mb) of memory
available for configuration storage. The “Memory Usage” section displays the “Total”
memory available, the memory “Used” and the available memory that is “Free” for use.

Boot Reason: the last action that caused the Touchscreen to boot. Reasons for reboot
could be due to a [Reset] button press on the Touchscreen I/O panel, power loss, etc.

N o t e :

The firmware version in the Touchscreen must be compatible with the firmware

version in the Paradigm Architectural Control Processor (P-ACP) for the two

devices to communicate.