Appendix 1 — Light Codes

ELAT100 Operator Light Codes (Auto)

Auto Mode (Standard Code)
• Safety hood must be closed
• Use Fwd and Rev to manually operate vise
• Insert rebar to engage touch probe to start

threading cycle

Auto Mode (in Cycle Code)
• Auto light will flash when in threading cycle
• Use Fwd to tighten vise if required
• Insert next rebar when cycle is completed

Auto Mode (Setup Required Code)
• Must reset for selected bar size
• Ensure bar size selection is correct and depress

Jog/Reset button to start setup

The Hand light will remain lit when threader is in setup.

A setup is required when selecting a different bar size
or when the cutting head is not in the proper position
to start a threading cycle.

Auto Mode (Worn Chaser Code)
Worn chaser warning!

Replace chasers as soon as possible.
• Ref Hand Mode instructions for resetting