beautypg.com

ERICO High Performance CADDY CAT HP J-Hook Assemblies User Manual

High performance caddy® cat hp j-hook assemblies

background image

Fig. 2

Fig. 1

Fig. 4

Fig. 5

Fig. 3

Fig. 6

Fig. 7

Fig. 8

Fig. 9

Fig. 10

Fig. 11

Fig. 12

Fig. 13

Fig. 14

Features:

- For use with Data Communication Cables only.

- Each assembly comes with a retainer.

- The CAT64HP holds 4-pair UTP cables; 300 Cat.5/5e or 300 fiber optic cables, or 185 Cat.6 cables.

- Provides strain relief and routes cables. Bend radius conforms to EIA®/TIA-568-A standard.

- Complies with UL®, cUL®, and NEC® requirements for structured cabling systems

- Complies with 1997 EIA/TIA 569-A.

Retainer Installation

TECHNICAL SUPPORT:

www.erico.com

CFS462_F

INSTRUCTION SHEET

1 OF 6

© 2011, 2012, 2013, 2014 ERICO

International Corporation.

WARNING:

ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

1.

www.erico.com and from your ERICO customer service representative.

ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

2.

All instructions must be completely followed to ensure proper and safe installation and performance.

3.

Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property

4.

damage, serious bodily injury and death.

Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.

5.

All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any

6.

other purpose.

NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:

a. Conformance to all governing codes.

b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified

engineer.

c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
EIA is a registered service mark of Electronic Components Association.

NEC is a registered trademark of, and National Electrical Code (NEC) standard is a copyright of the National Fire Protection Association, Inc.

UL and cUL are registered trademarks of UL LLC.

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

High Performance CADDY® CAT HP