beautypg.com

ERICO Bottom-Mount Duct Bracket, Narrow User Manual

Caddy® rod lock, Bottom-mount duct bracket, narrow

background image

Duct Width

+1-1/2" [38mm]

3/4" [19mm]

Typical

Duct Width

Duct Height

"L" Dimension

Maximum open position

Rotate lock nut counter clockwise

until reaches stopping position.

Step 1:

Lift duct into place.

Hold in desired position.

Step 2:

Install Duct Bracket by

pushing on to threaded rods.

Rectangular Duct Application

*Note: (4) screws are required for non-duct application.

**CRLD37BNEG (3/8") and CRLDM10BNEG (M10) were verified by

the SMACNA Testing and Research Institute to be acceptable

alternatives to the duct hanger systems prescribed in the

ANSI

®

/SMACNA HVAC Duct Construction Standards (HVAC-DCS)

3rd edition, Chapter 5, Tables 5-1 and 5-1M.

Step 0:

***P/2 = (Duct Height) + (Duct Width)

Max. Half of Duct

Perimeter***

3/8", M8, M10 Threaded Rod **

"L" Dimension

P/2 = 30"

L = 10ft [3m] L = 8ft [2.4m]

L = 5ft [1.5m]

P/2 = 72"

P/2 = 96"

P/2 = 120"

--

P/2 = 168"

--

--

P/2 = 192"

--

--

Part Number

Article

Number

Rod Size

Load Rating for

general applications*

( 3.0 safety factor)

CRLD37BNEG

N/A

3/8"

1,400 lbs [6,200N]

CRLDM8BNEG

390024

M8

650 lbs [2,900N]

CRLDM10BNEG

390025

M10

1,400 lbs [6,200N]

TECHNICAL SUPPORT:

www.erico.com

CFS482_E

INSTRUCTION SHEET

1 OF 2

© 2013, 2014 ERICO International Corporation.

CADDY® ROD LOCK

Bottom-Mount Duct Bracket, Narrow

WARNING:

ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

1.

www.erico.com and from your ERICO customer service representative.

ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

2.

All instructions must be completely followed to ensure proper and safe installation and performance.

3.

Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property

4.

damage, serious bodily injury and death.

Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.

5.

All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any

6.

other purpose.

NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:

a. Conformance to all governing codes.

b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified

engineer.

c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
ANSI is a registered trademark of American National Standards Institute.

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.