Gs[n] - gain scheduling, Simpliq – ElmoMC SimplIQ Command Reference User Manual
Page 67

GS[N] - Gain Scheduling
Purpose: 
Defines the gain scheduling process. 
SimplIQ
drives are scheduled according to the controller and the command states. This
may be necessary due to either the difference between the low-speed behavior and the 
high-speed behavior of the plant or because the inertia changes with position 
dependence. The process of assessing the situation and varying the controller parameters 
online accordingly is called “gain scheduling.” 
The following table lists the gain scheduling parameters. Unused indices are reserved for 
compatibility with older drives. 
Parameter Description
Values
GS[0]
No encoder count over which speed 
loop is opened 
0…500
GS[1]
Minimum speed command for speed 
and dual gain scheduling (counts/sec) 
0…16*62*256 internal speed units 
(1 speed unit = counts/Ts/2^16) 
GS[2]
Use scheduled gains: 
0: No 
64: Yes 
0, 64
GS[4]
Upward gain of gain scheduling filter
0…32,767
GS[5]
Downward gain of gain scheduling 
filter 
0…32,767
GS[9]
NL factor for position controller
0…60,000,000
GS[10]
Position error coefficient for position 
gain scheduling to raise gains 
0…1,200
GS[14]
Maximum speed error for which KP[N] 
is cleared in speed controller if no 
encounter count exceeds GS[0] 
0…2
31
-1
GS[15]
Gain scheduling step: 
0: 256 
1: 128 
N: 256/2
N
0…3
Table 3-15: Gain Scheduling Parameters
The GS[N] array is normally programmed by the Composer IDE. Manipulate it