ElmoMC SimplIQ Command Reference User Manual
Page 52

Error
Code
Error String / Description
Example / Remedy
111
KV[N] vector is invalid.
Invalid values in KV[N] parameters.
Refer to the “Advanced Filter”
chapter in the
SimplIQ
Software
Manual. If the vector was
configured by the Composer
auto-tuning wizard, email
Technical Support for assistance.
112
KV[N] defines scheduled block but
scheduling is off.
Invalid values in KV[N] parameters.
See the syntax of KV[N]
parameters in the “Advanced
Filter” chapter of the
SimplIQ
Software Manual. If the vector was
configured by the Composer
auto-tuning wizard, email
Technical Support for assistance.
113
Exp task queue is full.
Internal error during auto-tuning process.
114
Exp task queue is empty.
Internal error during auto-tuning process.
115
Exp output queue is full.
Internal error during auto-tuning process.
116
Exp output queue is empty.
Internal error during auto-tuning process.
117
Bad KV setting for sensor filter.
Invalid setting for KV[76]…KV[87].
See
KV
command section of this
manual.
118
Bad KV vector
This can happen when KV
parameters are not set according
to the correct feedback with
either length or value restriction.
119
Bad Analog sensor Filter
When the filter KV, set for analog
feedback, is beyond its legal
range.
120
Bad number of blocks for Analog sensor
filter
When the analog sensor filter
contains a wrong number of
blocks.
121
Analog sensor is not ready
When the initiation procedure of
the Analog sensor was not
completed, and the motor is
being enabled.
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-39