AN[N] - Analog Inputs Array
Purpose:
AN[1] reports the analog input #1 value after offset correction (AS[1]), in volts.
AN[2] reports the analog input #2 value after offset correction (AS[2]) in volts.
AN[3] reports the measured current in the motor A phase, in amperes.
AN[4] reports the measured current in the motor B phase, in amperes.
AN[5] reports the measured current in the motor C phase, in amperes.
AN[6] reports the line voltage value, in volts.
AN[7] reports the duty cycle value of the PWM signal after offset correction in
fractional units
Attributes:
Type:
Status report, Real
Source:
Program, RS-232, CANopen
Restrictions: None
Unit modes: All
Typical applications:
1. Reading external sensors that provides +/- 10V
2. Reading analog or PWM references for either velocity or current
3. Reading phase currents and line voltage
Note:
Analog input #1 serves as reference input for analog torque or analog
velocity command while in auxiliary reference mode (RM=1).
AN[7] is available after the first MO=1.
Each of Elmo’s
SimplIQ
drives support a different number of analog inputs.
For specific details consult the drive’s Installation Guide.
See also:
AG[N]
,
AS[N], PW[N]
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-8