Rr - activate recorder / get recorder status – ElmoMC SimplIQ Command Reference User Manual
Page 141

RR - Activate Recorder / Get Recorder Status
Purpose:
Launches the recorder, kills an on-going recording process or retrieves the recorder
status. The RR command has the following options:
RR Value
Meaning
0
Kill the recorder (do nothing if the recorder is not active).
1
Start recording at the next BG command.
2
Start recording immediately.
3
Arm the recorder with the trigger settings of the RP[N] parameters.
Table 3-43: RR Command Options
As a status report, RR may return the following values:
RR Report Meaning
-1
There is no valid data in the recorder.
0
The recorder action is complete and it is loaded with valid data.
1 - 3
Waiting for the completion of RR=1, RR=2 or RR=3, respectively. The
report value 3 does not indicate if the recorder is already recording or
just waiting for a trigger. If this differentiation is required, use the SR
command.
Table 3-44: RR Reports
Attributes:
Type: Parameter,
Integer
Source:
Program, RS-232, CANopen
Restrictions: None
Default value: -1,
Non-volatile
Range: [0…3]
Unit modes: All
Activation: Immediate
See also:
BH
,
RP[N]
,
RC
,
RG
,
RL
,
RR
Reference chapter in the
SimplIQ
Software Manual:
Chapter 7.4, “The Recorder”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-128