Pt - position time command – ElmoMC SimplIQ Command Reference User Manual
Page 129

PT - Position Time Command
Purpose:
Specifies that the next BG will start a PT (Position - Time) tabulated motion and defines
the starting index in the QP[N] array.
In a PT motion, a new position reference value is picked from the QP[N] array once per
MP[4] position controller sampling times. The motion is interpolated between the points
specified by the QP[N] array. The MP[N] parameters specify which indices of the QP[N]
array are used for the motion. After BG, the PT motion starts from position QP[PT].
A PT motion terminates when, in non-cyclical mode (MP[3]=0), the index of MP[2] is
reached, or if the PT buffer underflows (CANopen only). When a PT motion terminates,
the motor is brought to a complete stop using the SD deceleration.
When a PT motion is executing, PT reads the presently executing index of the QP[N]
array.
Attributes:
Type: Command/Parameter,
Integer
Source:
Program, RS-232, CANopen
Restrictions:
MO=1, PT motion executing,
Advanced
model
only
Default value: None,
Volatile
Range: [1…1024]
Unit modes:
Position control (UM=3, 4, 5)
Activation: Next
BG
See also:
PV
,
MP[N]
,
QP[N]
,
QV[N]
,
QT[N]
Reference chapter in the
SimplIQ
Software Manual:
Chapter 12, ”The Position Reference Generator”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-116