ElmoMC SimplIQ Command Reference User Manual
Page 54

Error
Code
Error String / Description
Example / Remedy
137
Program already compiled.
An attempt was made to download a user
program before previous one was erased.
Use the CP command before
downloading a new user
program.
139
The number of breakpoints exceeds the
maximum number.
140
An attempt to set/clear breakpoint at the
non-relevant line.
Internal IDE error.
For every line of the text
program, there is a
corresponding lien of compiled
code. This error appears during
an attempt to set a breakpoint at
a non-corresponding line of
compiled code.
141
Boot identity parameters section is not
clear.
Internal error during download of boot
identity parameters.
142
Checksum of data is not correct.
Internal error during download of boot
identity parameters.
143
Missing boot identity parameters.
Internal error during download of boot
identity parameters.
144 Numeric
stack
underflow.
An attempt has been made to retrieve an
entry from an empty stack.
145 Numeric
stack
overflow.
An attempt has been made to push a value
to the numeric stack when it is full.
User program contains very
complex code requiring more
stack space than is available. It
may also be that there are too
many called subroutines.
An expression in the command
line of the interpreter is too
complex; it calls too many
functions, so that the numeric
stack has overflowed.
146 Expression
stack
overflow.
An attempt has been made to push a value
to the expression stack when it is full.
An expression in the command
line of the interpreter is too
complex: it calls too many
functions, so that the expressions
tack has overflowed.
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-41