ElmoMC SimplIQ Command Reference User Manual
Page 53

Error
Code
Error String / Description
Example / Remedy
127
Modulo range must be positive.
XM[2] is less or equal to XM[1] or
YM[2] is less or equal to YM[1].
128
Bad variable index in database - internal
compiler error.
Index of the variable in the database is not
correct.
An internal compiler error occurs
due to a corrupted database. In
such a case, email Technical
Support for assistance. Attach the
Composer date and version (found
in the Help menu) and the program
you attempted to compile.
129
Variable is not an array.
Cannot access a scalar variable defined
according to its index in square brackets as
an array in the user program.
Assume that a scalar variable has
been defined in the user program
as a:
long a;
The expression a[0]=1; is wrong
because a is defined as scalar and
not an array.
130
Variable name does not exist.
For
SimplIQ
internal use.
131
Cannot record local variables.
For
SimplIQ
drive internal use.
132
Variable is not an array.
For
SimplIQ
drive internal use.
133
Mismatched number of user/system
function input arguments.
An attempt was made to call user/system
function with the number of input
arguments not as defined.
• rnd(4.6,7.7) ; This
expression is wrong,
since system function
rnd() expects only one
input argument.
• Calling user function by
XQ command with
number of input
arguments not as defined
in user program.
134
Cannot run local label with XQ command.
XQ##START; when START is
defined in the user program
inside a user function it is
consider to be a local label and
therefore it is illegal to use it
with the XQ command.
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-40