beautypg.com

Video balancer – COATS Series XR 1800 Balancer User Manual

Page 40

background image

34 •

Important: Always read and follow the on-screen operating instructions.

Video Balancer

Machine Self-Test “Green Screen”

In the event of faulty wheel balancer operation, notify

a COATS

®

Service Technician of all the machine self

test readings. To view the self test screen, press the

key, select Special Functions option

, and

select Machine Self-Test option

.

Figure 56 - Machine Self-Test Screen

A - This line provides software version and other tech-

nical information.

B (Pos.) - An encoder check. The word UP should

appear when rotated clockwise and DOWN when
rotated in the opposite direction.

C (Dist) - Check for correct operation of the distance

arm gauge; the number increases when the gauge is
pulled out.

D (Sonar 1) - Check of the hood width sensor

(option): the number decreases when a surface is
brought closer to the sensor device.

E (Vco I) - Piezo Output.

F (Diam) - Check for correct operation of the diame-

ter gauge; the number increases when the offset arm
is rotated outward.

G (Sonar 2) - Check of the radial runout sensor

(option): the number decreases when a surface is
brought closer to the sensor device.

H (Vco E) - Piezo Output.

J (Sonar 3) - Check of the lateral runout sensor

(option): the number decreases when a surface is
brought closer to the sensor device.

K - Toggle the Sonar 1/3 screen option

,to view

either Sonar 1 or Sonar 3 diagnostic information.

3

7