COATS Kit 8113887 XR 1800 Upgrade to XR 1850 User Manual
Parts identification, Instructions
Parts Identification
Qty.
Description
1
Lateral Runout Kit
1
Printer Bracket Kit
1
Printer Kit
1
Printer Cable
1
115V Power Cord Assembly
1
Duplex Receptacle Bracket
1
115V Female Duplex Receptacle
1
Caution 115V Duplex Receptacle Decal
2
1/4-20 Hex Nylok Nut
1
Danger Laser Decal
1
6-32 Patch Lock Screw
1
1850 Software
1
1800/1850 Operating Manual
1
1800/1850 Parts Identification Manual
1
Temp Instruction - 16 Bit PCB & Metal Arm
Instructions
1. Align bottom of printer bracket with bottom of
gauge panel. Position as shown and mark location for
two holes in monitor tower using slots in printer
bracket.
2. Drill two 0.228 diameter holes in monitor tower. Be
sure cabling inside tower is clear.
3. Mount bracket and printer per instructions in
8113881 Printer Kit and 8113883 Printer Bracket Kit
except route Printer Connector Cable through hole at
bottom of monitor tower.
4. Mount the duplex receptacle, bracket, and cable as
shown. Plug in printer adapter and route printer cabling
as shown in picture. Connect cable 80180125 from main
PCB to printer serial connector. Place 8113891 decal on
top of duplex receptacle bracket.
5. Remove weight tray. Locate and drill two 9/32-inch
(0.281) diameter and one 11/16-inch (0.687) diameter
holes through front of cabinet per dimensions shown
below.
XR1800 Upgrade to XR1850
Kit 8113887
COATS, Inc. • Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565
(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com
8113885 01 08/04 Page 1 of 2
© COPYRIGHT 2004 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.
Route Printer
Connector
Cable Through
Hole
Parallel
with Floor
3/4"
1-1/2"
7-3/8"
15-1/8"
20"
11/16"
(0.687 Dia.)
9/32"
(0.281 Dia.)
2 Holes
2-1/2"