beautypg.com

Video balancer – COATS Series XR 1800 Balancer User Manual

Page 38

background image

32 •

Important: Always read and follow the on-screen operating instructions.

Video Balancer

Error

Err.13

Err.14

Err.17

Err.18

Err.15 /

Err.16 /

Err.19

Err.20

Err. 30

Err.40,

41, 42,

43

Err.45,

46, 47,

48

Err.50,

51, 52,

53

Err.54

Symptom

Error in the unbalance measure-

ment.

Over ranging - too much unbal-

ance

Wheel stopped before it was

positioned or before taking

runout reading.

Clock error

Error in the creating of the

runout graph.

Error in the reading of the val-

ues which are used to create

the runout graph.

Error in the writing procedure of

the cursor for the current value

of the runout graph.

Error in the Sonar reading.

Sonar did not read any value.

Check

1. Press

and respin. Check PHASE, VCO, VCI in MACHINE SELF-TEST.

2. Check the piezo pick-ups connection. (electrical & mechanical)

3. Check the balancer spindle connections.

4. Mount a wheel having a known unbalance (lower than 3.5oz or 100

grams) and check the balancer readings.

5. Replace the PC board.

A.) Follow screen instructions for “heavy side” down balancing to bring

wheel unbalance into range and then balance normally.

B.) Follow instructions 1 thru 5 above.

1. Wheel too light - not enough inertia. Use heavier wheel.

2. Check positioning of sonar unit behind wheel.

1. Replace the PC board

1. Execute a new runout measurement.

1. Execute a new runout measurement.

1. Execute a new runout measurement.

1. Before taking the measurement, make sure that the RADIAL

RUNOUT SONAR is properly positioned.

2. Check the RADIAL RUNOUT SONAR connection. Unplug and replug at

pwer PCB.

3. Check the power supplies on the power board.

4. Replace the RADIAL RUNOUT SONAR.

5. Check that the wheel doesn’t stop before making at least 4 to 5

complete turns after the first breaking impulse.

6. Check belt tightening.

7. Replace the PC board

EXIT