Conversion Instructions
Phase-3 to Phase-1
for the COATS IBS 2000

COATS, Inc. • Hennessy Industries • P.O. Box 3002, 1601 J.P. Hennessy Drive, LaVergne, TN 37086-1982

(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX

112355 6/97 rev.0

© COPYRIGHT 1997 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.

Disconnect unit from electric power source
before performing any service on the com-
ponents. When the unit is plugged in, high
voltages are present inside the unit, creat-
ing the risk of serious electric shock or
lethal electrocution.

Tools Required

• #2 Phillips Screwdriver

• 1/4 inch Flathead Screwdriver

• 3/8 inch Nutdriver

• Wire Cutters

Instructions

1. Turn the balancer off and unplug it from the

power source.

2. Remove the weight tray and fire shield.

3. Install the capacitor assembly (part no. 112356, in

the conversion kit) using the provided hardware (part
no. 112357).

4. Remove the green connector from the motor

control printed circuit board (PCB), location P4.

5. Plug the green connector from the new capacitor

assembly into the motor control PCB at location P4.

6. Rewire the power cord with the single-phase

plug (part no. 305076) and configure the internal
wiring according to the diagram.

Note: Cut the unused wire at both ends of the

power cord.

7. Plug the balancer in and verify correct operation.

IF THE MOTOR SPINS BACKWARDS: Swap any 2

wires at the green connector at location P2 on the
motor control PCB (you will need the flathead screw-
driver for this).

8. Reinstall the fire shield and weight tray.

WARNING