CHAMPION UL-130 Manual User Manual
Page 42

32
1. The chemical dispensing pumps are located on a center bracket behind the lower-front
access panel.
2. Each pump is equipped with 6 feet [1.8 m] of supply tubing, stiffener tubes, and strainers.
3. A RED label marked DETERGENT, a BLUE label marked RINSE-AID and a WHITE Label
marked SANITIZER identify the chemical lines.
4. The chemicals enter the wash tank compartment through a fitting located on the right-hand
side for the wash compartment.
Initial Start-Up - Model UL130
Pumps and Injection Points - Detergent, Rinse-aid and Sanitizer
Dispensing Pumps - UL130
The chemical dispensing pick-up tubes are stowed at
the rear of the dishwasher.
On the UL130, chemicals enter the wash tank
through a fitting on the right-hand side of the tank.
UL130
DETERGENT
RINSE-AID
and
SANITIZER
INJECTION
POINT
! ATTENTION !
Contact a chemical supplier for detergent and rinse-aid chemicals.
The supplier can adjust the chemical dispensing pumps too.
CHEMICAL
PICK-UP
TUBES
! VERY IMPORTANT !
ALWAYS USE A COMMERCIAL-GRADE NON-CHLORINATED DETERGENT.
PLACE THE CHEMICAL SUPPLY CONTAINERS AS CLOSE TO THE MACHINE AS POSSIBLE.
DO NOT ELEVATE THE CHEMICAL CONTAINERS ABOVE THE FINISHED FLOOR.