10
Initial Start-up - Model UH130B, UH230B
To refill the booster tank:
1. Remove the lower front panel.
2. Make sure the door is closed.
3. Locate the booster fill switch
mounted on the bracket in the
center of the machine. Note
that the switch is in the OFF
position.
4. DO NOT push the dishwasher
power switch on the control
panel to the ON position.
5. Turn the main power
breaker or disconnect
switch to the dishwasher
ON.
Continued on next page
Booster Fill Switch - (Filling the booster tank for the first time)
Models UH130B and UH230B only
! VERY IMPORTANT !
Models UH130B and UH230B
THE BUILT-IN BOOSTER TANK WAS DRAINED BEFORE SHIPMENT AND
MUST BE REFILLED BEFORE OPERATING THE DISHWASHER.
A BOOSTER FILL SWITCH IS LOCATED BEHIND THE LOWER FRONT PANEL ON THE
MACHINE TO REFILL THE BOOSTER TANK.
CAUTION:
Do not turn the dishwasher power switch on when refilling the booster
tank to prevent permanently damaging the booster heater element.
The Booster Fill Switch is located on the front center bracket
behind the lower front access panel.