beautypg.com

Booster heater element – CHAMPION UL-130 Manual User Manual

Page 16

background image

6

Installation - Model UH130, UH130B, UH230, UH230B

1. Disconnect the main incoming power at the main service disconnect breaker or switch.
2. Remove the lower front access panel.
3. Locate the 1H3 booster heater wire stored on the right-side of the booster tank.
4. Disconnect the existing booster heater wires and change the booster heater element

jumpers as shown in the illustration below

5. Connect wires 1H1, 1H2, and 1H3 as shown below.

6. A replacement 3PH data plate is stowed on the back of the lower front access panel.

Replace the existing 1PH data plate on the front of the panel with the new 3PH data plate.

Discard the 1PH data plate.

1H1

1H2

1H3

Booster Heater

Connected for 1PH

1H1

Booster Heater

Connected for 3PH

1H2

1H3

Wire not

connected

Booster heater element connections shown for 1 phase and 3 phase operation.

Booster Heater Element -

UH130, UH130B, UH230, UH230B

Field Conversion from Single to Three Phase Operation (continued)

A replacement three phase data plate is stowed

on the back of the machine lower front access panel.

This manual is related to the following products: