CHAMPION UL-130 Manual User Manual
Page 12

2
Installation - Model UH130, UH130B, UH230, UH230B
(Single Phase) Electrical Connections -
UH130, UH130B, UH230, UH230B
WARNING:
Electrocution or serious injury may result when working on an
energized circuit.
Disconnect power at the main breaker or service disconnect switch
before working on the circuit.
Lock-out and tag the breaker or service disconnect switch to
indicate that work is being performed on the circuit.
! ATTENTION !
A qualified electrician must connect the main incoming power to the dishwasher in
accordance with all local codes and regulations or in the absence of local codes in
accordance with the National Electrical Code or the Canadian Electrical Code.
! VERY IMPORTANT !
ALL DISHWASHERS ARE SHIPPED FOR SINGLE PHASE OPERATION UNLESS SPECIFIED
FOR THREE PHASE AT TIME OF ORDER.
A label is attached to the main terminal block alerting the electrician that the
dishwasher is wired for single phase operation.
The dishwasher can be converted from single to three phase operation. Refer to the
instructions on pages 4-5.
1. Power connections are made at the
Main Terminal Block (MTB) located
at the lower right-hand side of the
dishwasher directly behind the lower
front access panel.
2. Remove the MTB cover and 2 screws
holding the MTB to the machine base
3. Pull the MTB up and forward to make
the electrical connections.
4. Provide a 3 ft. service loop in the supply
cable for machine servicing.
5. Re-install the MTB and the lower
front access panel to complete the
installation.
6. Refer to the connection diagrams on the
next page for 1PH wiring.
Main Terminal Block (MTB)
(shown extended from machine)
!