UH130, UH130B, UH230, UH230B - Digital Temperature Display Codes
DISPLAY CODES
WASH TEMP
RINSE TEMP
WASH TEMP
RINSE TEMP
RINSE TEMP
WASH TEMP
b E
b E E
b
Booster Display Codes
CAUSE
Booster overtemp lockout
because booster temperature
is greater than 210˚F.
NOTE:
Booster is locked out
for 10 minutes before being
re-energized.
Booster therrmistor is
defective or disconnected,
broken wires.
NOTE:
After the therrmistor
is reconnected, there is a 5
second delay before the
display is re-energized.
Error Codes for Booster and Final Rinse Thermistors Only.
1 5 0
1 5 0
1 5 0
Both booster and final rinse
display thermistors are
defective, unplugged, or open
or broken wires between the
display and thermistor.
NOTE:
After a therrmistor
is reconnected, there is a 5
second delay before the
display is re-energized.